ATH 3204 M
- Inlet flange
- DN 320 ISO-F, VG 350, VG 300 or DN 300 CF-F
- Mass
- 80-100 kg
- Temperature control
- None
Pfeiffer ATH 3204 M repair
We service every Pfeiffer ATH 3204 M. Check the version on your pump against Pfeiffer Vacuum's list below, then request service.
Is it yours?
Pfeiffer Vacuum's instruction manual lists two versions for this model. Compare them with the version on your pump.
ATH 3204 M
ATH 3204 MT
| Bearing type | Maglev Pfeiffer writes: magnetically levitated turbomolecular pump |
|---|---|
| Electronic drive unit | Built in Pfeiffer writes: integrated electronic drive unit |
| Inlet flange options | DN 320 ISO-FVG 350VG 300DN 300 CF-F |
| Outlet flange | DN 40 ISO-KFDN 50 ISO-KF |
| Cooling | Water |
| Pumping speed, nitrogen | 3050 l/s with the DN 320 ISO-F or the VG 350 inlet flange |
| Rated speed | 25000 rpm |
| Maximum power | 1200 W maximum power consumption for start-up |
| Mass | 80-100 kg for the ATH 3204 M103 kg for the ATH 3204 MT |
Source: Pfeiffer Vacuum's instruction manual "Operating instructions ATH 2804 - ATH 3204 M/MT", number 121608OEN, edition 07. Outlet flange, Maximum power, Mass: Pfeiffer Vacuum's product leaflet "ATH 2804/3204 M/MT, Turbomolecular vacuum pumps", dated October 26, 2026. Checked on November 27, 2026.
Maximum power: Pfeiffer Vacuum's product leaflet prints 1200 W as the most the ATH 3204 M draws at start-up, and its instruction manual prints 1100 W. The product leaflet is the newer of the two, so this sheet shows its figure.
Mass: Pfeiffer Vacuum's product leaflet prints 80-100 kg for the ATH 3204 M, and its instruction manual prints 80 kg. The product leaflet is the newer of the two, so this sheet shows its figure.
Outlet flange: Pfeiffer Vacuum's product leaflet names DN 40 ISO-KF, DN 50 ISO-KF for the ATH 3204 M, and its instruction manual names DN 40 ISO-KF. The product leaflet is the newer of the two, so this sheet follows it.
Every stage is done in our shop in Tempe, Arizona, from decontamination to final testing. Nothing is sent out.
Our shop has the tooling and the technical knowledge for larger maglev pumps.
It is built into this pump. We repair turbo pump controllers, and the pump and its controller are matched and tuned as one set.
Vibration analysis, balancing, vacuum testing and leak checks, by pump type. The test records stay with the job.
Call (480) 820-5200 before you ship the pump. We tell you how to prepare it.
Pfeiffer Vacuum's instruction manual shows that the ATH 3204 M has no temperature management system. The ATH 3204 MT has a temperature management system, which can be set up to 85 °C.
It is built into the pump. Pfeiffer calls this an integrated electronic drive unit, the OBC.
Yes. We service all turbomolecular pump brands and models.
The version of the pump and a few photos. Call us before you ship it.
Turbo Pump Service by Trotec is run by Trotec Solutions, Inc., an independent service provider. We do not make this pump. Pfeiffer and the other brand and model names on this page are trademarks of their owners. We use them only to identify the pumps we service.
Have the version of your pump ready, and a few photos.