Skip to the content

Osaka Vacuum turbo pump repair

Repair for Osaka Vacuum turbomolecular pumps

We repair Osaka Vacuum turbomolecular pumps of every line. Every stage of the repair is done in our own shop in Tempe, Arizona.

Osaka Vacuum turbo pump models with a service sheet

The series names are Osaka Vacuum's own, as its lineup page heads them. A model name with a link has a service sheet.

Osaka Vacuum TGkine-B series

Maglev. Controller: built in.

Models of the TGkine-B series, with the figures from Osaka Vacuum's product pages
Model Model codes Inlet flange Pumping speed, nitrogen Mass
TGkine1700M-B TGkine1704M-B, TGkine1705M-B ISO-B200; VG200 1650 L/s 65 kg
TGkine2200M-B TGkine2204M-B, TGkine2205M-B ISO-B250; VG250 2200 L/s 62 kg
TGkine3300M-B TGkine3304M-B, TGkine3305M-B ISO-B320; VG300 3300 L/s 70 kg with the ISO-B320 inlet flange; 69 kg with the VG300 inlet flange
TGkine3400M-B TGkine3404M-B, TGkine3405M-B VG350 3300 L/s 72 kg
TGkine3800M-B TGkine3804M-B, TGkine3805M-B ISO-B320; VG300 3600 L/s Not shown
TGkine4200M-B TGkine4204M-B, TGkine4205M-B VG350 4200 L/s 75 kg

Mass of the TGkine3800M-B: not shown. Where Osaka Vacuum's product page prints two figures with no inlet flange beside them, this page leaves the mass out.

Osaka Vacuum TGkine-R series

Maglev. Controller: separate.

Models of the TGkine-R series, with the figures from Osaka Vacuum's product pages
Model Model codes Inlet flange Pumping speed, nitrogen Mass
TGkine2200M-R TGkine2204M-R, TGkine2205M-R ISO-B250; VG250 2200 L/s 59 kg
TGkine3300M-R TGkine3304M-R, TGkine3305M-R ISO-B320; VG300 3300 L/s Not shown
TGkine3400M-R TGkine3404M-R, TGkine3405M-R VG350 3300 L/s 67 kg
TGkine3800M-R TGkine3804M-R, TGkine3805M-R ISO-B320; VG300 3600 L/s Not shown
TGkine4200M-R TGkine4204M-R, TGkine4205M-R VG350 4200 L/s 70 kg

Mass of the TGkine3300M-R and TGkine3800M-R: not shown. Where Osaka Vacuum's product page prints two figures with no inlet flange beside them, this page leaves the mass out.

Osaka Vacuum TG-M series

Maglev. Controller: separate.

Models of the TG-M series, with the figures from Osaka Vacuum's product pages
Model Model codes Inlet flange Pumping speed, nitrogen Mass
TG390M TG390M VG100; ISO-B100; CF100 340 L/s 14 kg, with a VG or ISO-B inlet flange; 17 kg, with a CF inlet flange, or for the corrosion-resistant type
TG420M TG420M VG150; ISO-B160; CF160 400 L/s 14 kg, with a VG or ISO-B inlet flange; 17 kg, with a CF inlet flange, or for the corrosion-resistant type
TG900M TG900M VG150; ISO-B160; CF160 900 L/s 34 kg, with a VG or ISO-B inlet flange; 42 kg, with a CF inlet flange, or for the corrosion-resistant type
TG1300M TG1300M VG200; ISO-B200; CF200 1300 L/s 34 kg, with a VG or ISO-B inlet flange; 42 kg, with a CF inlet flange, or for the corrosion-resistant type
TG2400M TG2400M VG250; ISO-B250 2400 L/s 45 kg, standard model; 54 kg, corrosion-resistant model

Osaka Vacuum TG-M7 series

Maglev. Controller: separate.

Models of the TG-M7 series, with the figures from Osaka Vacuum's product pages
Model Model codes Inlet flange Pumping speed, nitrogen Mass
TG397M TG397M VG100; ISO-B100; CF100 340 L/s 16 kg, with a VG or ISO-B inlet flange; 19 kg, with a CF inlet flange, or for the corrosion-resistant type
TG427M TG427M VG150; ISO-B160; CF160 400 L/s 16 kg, with a VG or ISO-B inlet flange; 19 kg, with a CF inlet flange, or for the corrosion-resistant type
TG907M TG907M VG150; ISO-B160; CF160 900 L/s 37 kg, with a VG or ISO-B inlet flange; 45 kg, with a CF inlet flange, or for the corrosion-resistant type
TG1307M TG1307M VG200; ISO-B200; CF200 1300 L/s 37 kg, with a VG or ISO-B inlet flange; 45 kg, with a CF inlet flange, or for the corrosion-resistant type

Model names and series: Osaka Vacuum's lineup page for its magnetically levitated turbo molecular pumps. Figures: each model's product page, named on its service sheet. Checked on November 28, 2026.

How Osaka Vacuum names its turbo pumps

Osaka Vacuum calls its maglev pumps magnetically levitated turbo molecular pumps. Its page on them says the rotor is held by electromagnets, and the magnetic bearing controls all five axes. Its lineup has four series of them: TGkine-B, TGkine-R, TG-M and TG-M7, and heated versions of some.

This catalog has a service sheet for the six TGkine-B models, from the TGkine1700M-B to the TGkine4200M-B. Each has its controller and power supply built into the pump. Each comes in two model codes that differ by their outlet flange, KF40 or KF50, and each code is a card on the sheet.

The five TGkine-R models, from the TGkine2200M-R to the TGkine4200M-R, run from a separate, rack-mounted controller: the TC0321M, the TC0331M or the TC0341M. Each sheet names its controller.

The five TG-M models, from the TG390M to the TG2400M, and the four TG-M7 models, from the TG397M to the TG1307M, run from a separate controller too: the TC010MB for every TG-M model, and the TC0301M or the TC0311M for the TG-M7 models. Each comes with VG, ISO-B and CF inlet flanges, but the TG2400M, which comes with VG and ISO-B. Where the page gives a figure by flange or by type, such as the mass, the sheet gives each figure with what it is for.

The heated versions, the TGkine-MI and TG-MI series, come next, and then the ball bearing pumps. We service all of them now.

What we need to quote an Osaka Vacuum pump repair

  • The model of the pump, for example TGkine2200M-B.
  • Its model code, for example TGkine2204M-B. Osaka Vacuum's product pages list two codes for each model.
  • For a pump with a separate controller, the controller that runs it, for example TC0321M.
  • A few photos of the pump.

Call (480) 820-5200 before you ship a pump. We tell you how to prepare it.

Service for Osaka Vacuum pumps in our Tempe shop

Decontamination

Done in-house. An outside waste service collects the contaminants.

Testing

Vibration analysis, balancing, vacuum testing and leak checks, by pump type.

Controller

We repair turbo pump controllers. The pump and its controller are matched and tuned as one set.

Records

The service history and the test records are kept together for each job.

Nothing is sent out. See how a repair works.

Questions about Osaka Vacuum turbo pump repair

Which Osaka Vacuum turbo pumps do you repair?

All of them: the TGkine, TG-M and TG-M7 maglev pumps, and the others.

Is an Osaka Vacuum TGkine pump a maglev pump?

Yes. Osaka Vacuum calls it a magnetically levitated turbo molecular pump. Its page says the rotor is held by electromagnets, and the magnetic bearing controls all five axes.

My Osaka Vacuum pump is not in the catalog yet. Do you service it?

Yes. We service all turbomolecular pump brands and models. Call us with the model and the model code.

About brand names

Turbo Pump Service by Trotec is run by Trotec Solutions, Inc., an independent service provider. We do not make these pumps. Osaka Vacuum and the other brand and model names on this page are trademarks of their owners. We use them only to identify the pumps we service.

Request service for your Osaka Vacuum turbomolecular pump

Have the model and the model code of the pump ready, and a few photos.

Last updated: