Leybold TURBOVAC 850 i repair

Repair for the Leybold TURBOVAC 850 i hybrid turbomolecular pump

  • TURBOVAC i
  • Hybrid
  • Frequency converter built in

We service every Leybold TURBOVAC 850 i. Check the part number on your pump against Leybold's list below, then request service.

Is it yours?

Which TURBOVAC 850 i is yours?

Leybold's catalog lists four part numbers for this model. Compare them with the part number on your pump.

840071V1000

Inlet flange
DN 160 ISO-K
Mass
14.6 kg
Version
TURBOVAC i, with RS 485, USB+ and a 15-pin digital I/O interface

840081V1000

Inlet flange
DN 160 CF
Mass
19.6 kg
Version
TURBOVAC i, with RS 485, USB+ and a 15-pin digital I/O interface

840071V3300

Inlet flange
DN 160 ISO-K
Mass
15.1 kg
Version
TURBOVAC iX, with a vacuum system controller, RS 485, USB+ and a 15-pin digital I/O interface

840081V3300

Inlet flange
DN 160 CF
Mass
20.1 kg
Version
TURBOVAC iX, with a vacuum system controller, RS 485, USB+ and a 15-pin digital I/O interface

Key data from Leybold for the TURBOVAC 850 i

Bearing type Hybrid Leybold writes: hybrid rotor suspension (mechanical/magnetic)
Frequency converter Built in Leybold writes: integrated frequency converter
Inlet flange options DN 160 ISO-KDN 160 CF
Outlet flange DN 25 ISO-KF
Cooling Convection, standardAir or water, as an option
Pumping speed, nitrogen 720 l/s
Rated speed 49 200 rpm operating speed
Maximum power 600 W maximum power consumption of the integrated drive electronics
Mass 14.6 kg for the 840071V100019.6 kg for the 840081V100015.1 kg for the 840071V330020.1 kg for the 840081V3300 pump with its frequency converter

Source: Leybold's catalog "Leybold Full Line Catalog (Edition 2025/2) - High Vacuum Pumps", number 240.00.02. Checked on November 28, 2026.

Service for the TURBOVAC 850 i in our Tempe shop

In-house repair

Every stage is done in our shop in Tempe, Arizona, from decontamination to final testing. Nothing is sent out.

Hybrid pumps

A hybrid pump has one magnetic bearing and one ball bearing. We repair all three bearing types: maglev, hybrid and ball bearing.

Frequency converter

It is built into this pump. We repair turbo pump controllers, and the pump and its controller are matched and tuned as one set.

Tests and records

Vibration analysis, balancing, vacuum testing and leak checks, by pump type. The test records stay with the job.

What to tell us about your TURBOVAC 850 i

  • The full part number of your pump, for example 840081V3300.
  • A few photos of the pump.

Call (480) 820-5200 before you ship the pump. We tell you how to prepare it.

Questions about the TURBOVAC 850 i

Where is the frequency converter of the TURBOVAC 850 i?

It is built into the pump. Leybold calls this an integrated frequency converter.

Do you service every Leybold TURBOVAC 850 i?

Yes. We service all turbomolecular pump brands and models.

What do you need from me to quote a TURBOVAC 850 i repair?

The full part number of the pump and a few photos. Call us before you ship it.

About brand names

Turbo Pump Service by Trotec is run by Trotec Solutions, Inc., an independent service provider. We do not make this pump. Leybold and the other brand and model names on this page are trademarks of their owners. We use them only to identify the pumps we service.

Request service for your Leybold TURBOVAC 850 i

Have the part number of your pump ready, and a few photos.